The new Valleylab™ LS10 Electrosurgical Generator* provides you with the essential power you need. Both affordable and portable, the LS10 generator makes the next generation of LigaSure™ vessel sealing technology accessible to customers around the world. The platform is designed for open and laparoscopic surgical procedures and includes:

TissueFect™ detection technology in all modalities
LigaSure™ fusion technology for vessel sealing
With the Valleylab™ Exchange software update system, the unit can be easily updated on-site, providing surgeons, nurses, and patients with up-to-date, state-of-the-art technology.

Specialties using the Valleylab™ LS10 Generator include:

Colorectal
Urology
General Surgery
Plastic
Gynecology

GENERAL CHARACTERISTICS
Output configuration Isolated output
Cooling Natural and forced convection
Display System status indicator – circle LED (12 blocks) shows system status
System error indicator – triangle LED with exclamation mark
Instrument status indicator – LED above the LigaSure™ receptacle
Usage limit indicator – 2 with a line through it
Mounting A Covidien cart (UC8009) or a stable, flat surface
DIMENSIONS AND WEIGHT
Width 300 mm (11.81 inches)
Depth 377 mm (14.84 inches)
Height 105 mm (4.13 inches)
Weight 5 Kg (11 lbs)
INPUT POWER
100-120 Volt 220-240 Volt
  • Maximum VA – 400 VA
  • Input mains voltage, full regulation range 90-130 VAC
  • Input mains voltage, operating range 100-120 VAC
  • Mains line frequency range (nominal) 50 Hz to 60 Hz
  • Fuses (2) – 5 mm x 20 mm 8 A, 250 V fast blow
  • Maximum VA – 400 VA
  • Input mains voltage, full regulation range 180-264 VAC
  • Input mains voltage, operating range 210-240 VAC
  • Mains line frequency range (nominal) 50 Hz to 60 Hz
  • Fuses (2) – 5 mm x 20 mm 8 A, 250 V fast blow

 

Mode P-P Voltage Rated Load (Ohms) Maximum Power (Watts) Duty Cycle
LigaSure™ LigaSure™ 500 V 30 270 N/A
INPUT POWER
100-120 Volt 220-240 Volt
  • Maximum VA – 400 VA
  • Input mains voltage, full regulation range 90-130 VAC
  • Input mains voltage, operating range 100-120 VAC
  • Mains line frequency range (nominal) 50 Hz to 60 Hz
  • Fuses (2) – 5 mm x 20 mm 8 A, 250 V fast blow
  • Maximum VA – 400 VA
  • Input mains voltage, full regulation range 180-264 VAC
  • Input mains voltage, operating range 210-240 VAC
  • Mains line frequency range (nominal) 50 Hz to 60 Hz
  • Fuses (2) – 5 mm x 20 mm 8 A, 250 V fast blow